Signet 8860 Two-Channel Conductivity/Resistivity Controller

0
0

Conductivity /Resistivity /Salinity/TDS


Signet 8860 Two-Channel Conductivity/Resistivity Controller

The Signet 8860 Two-Channel Conductivity/Resistivity Controller is packed with a set of features and capabilities ideal for the real needs of water treatment applications. It accommodates two separate and independent input sources and can be powered with AC/DC voltage. The 8860 programs via a simple and intuitive menu system. The unit can also be programmed to measure a raw conductivity value by turning off the temperature compensation mode.

To control the process, the 8860 is equipped with four dry contact relays and three 4 to 20 mA output loops. Calculated measurements include Difference, Ratio, or % Rejection. Two of the relays may be converted into open collector outputs with the flip of a switch. Operating modes for the relays and open collector outputs are high, or low alarm, pulse, or special USP alarm mode. The 8860 is offered with a NEMA 4X/IP65 front panel with a self-healing window in a ¼ DIN package for easy panel installation.

Advantages:

•    Meets USP requirements for measuring raw conductivity, USP alarm mode
•    Dual sensor input
•    AC or DC powered
•    Display and/or control: μS, mS, PPM or PPB (TDS), kΩ, MΩ, % rejection, difference, ratio,°C or °F
•    Three fully scaleable 4 to 20 mA outputs
•    Two open collector outputs
•    Four programmable relays
•    Time delay relay function
•    Proportional pulse control capability
•    Compatible with ALL Signet conductivity electrodes
•    Programmable temperature compensation
•    NEMA 4X/IP65


Field of Application:

•    RO/DI System Control
•    Demineralizer Regeneration and Rinse
•    Scrubber, Cooling Tower & Boiler Protection
•    Chemical Concentration
•    Rinse Tank Water Quality
•    Desalination
•    Leak Detection
•    Aquatic Animal Life Support Systems
•    Aquaculture
•    Environmental Studies


Standards:

•    CE
•    FCC
•    UL
•    CUL
•    RoHS
•    China RoHS

Advantages:

•    Meets USP requirements for measuring raw conductivity, USP alarm mode
•    Dual sensor input
•    AC or DC powered
•    Display and/or control: μS, mS, PPM or PPB (TDS), kΩ, MΩ, % rejection, difference, ratio,°C or °F
•    Three fully scaleable 4 to 20 mA outputs
•    Two open collector outputs
•    Four programmable relays
•    Time delay relay function
•    Proportional pulse control capability
•    Compatible with ALL Signet conductivity electrodes
•    Programmable temperature compensation
•    NEMA 4X/IP65